Tank
Filling
Systems

Mini
SmartPump

Request Quote
 

Mini
SmartPump

The Simplex Mini SmartPump is a tank fill pump with intelligence. The Mini SmartPump is a factory packaged system for transfer of fuel from gravity trucks to storage tanks and control of filling operations to prevent overfill and allow for full draining of the truck delivery hose. The Mini SmartPump provides a ready means of ground level connection of the fill hose, and captures spills that may occur at the fill point during filling operations. The Mini SmartPump includes a 2 gpm fuel transfer pump and intelligent pump controls. Optional 7, 10, 17, and 25 gpm pumps are available. The unique design and intelligence of the Mini SmartPump allows full and easy draining of the truck fill hose prior to disconnect. The SmartPump detects the 90% level, stops filling operations and activates an alarm. The Mini SmartPump allows the operator to continue filling and/or drain the fill hose up to the 95% level at which time all filling operations are locked out and an alarm is activated. A leak detection circuit prevents filling of leaking tanks. Visual and audible level and leak alarms are provided.

The Simplex Mini SmartPump is available for the filling of one aboveground fuel storage tank with Class-II liquids, those having a flash point greater than 100° F (fuel oil, diesel fuel, and kerosene).

How it works:

1. Delivery truck arrives and driver proceeds to Mini SmartPump to make fuel delivery.
2. Connect ground cable.
3. Unlock fill box and control box.
4. Turn on controller.
5. Connect delivery hose to hose coupling.
6. Open valve on truck.
7. Open Mini SmartPump inlet valve.
8. Open Mini SmartPump outlet valve.
9. Start Mini SmartPump.
10. Fuel is delivered to tank.
11. At 90% level, audible and visual alarm activates and alerts driver, Mini SmartPump stops.
12. Driver may stop delivery at this point.
13. Driver can restart Mini SmartPump by pressing “override” pushbutton and pressing “Pump Start” pushbutton. Pump will run for 30 second intervals.
14. Driver can continue filling or drain delivery hose at this time.
15. To drain hose, driver closes truck valve and breaks hose connection at tank and allows SmartPump to empty hose.
16. Driver may restart Mini SmartPump in 30 second intervals, but all filling and hose draining operations must be ended and truck valve closed prior to reaching 95% level.
17. At 95% level, audible and visual alarm activates and SmartPump stops. SmartPump can not be restarted.
18. Close Mini SmartPump outlet valve.
19. Close Mini SmartPump inlet valve.
20. Disconnect delivery hose and ground cable.
21. Turn controller off.
22. Close and lock Mini SmartPump doors.
23. Proceed to next delivery, where, hopefully, the owner has had the foresight to install a Simplex Mini SmartPump.

Mini SmartPump
Mini SmartPump with doors open

Specifications

Fitting size: 2"
Spill containment: 20 gallons
Paint: white epoxy
Level transmitter fitting: 2"

Mini SmartPump Dimensional Drawing


Simplex Mini SmartPump includes:

Steel, weatherproof, lockable containment box with hinged door

External stainless steel ground stud for attachment of delivery truck ground cable

2" quick disconnect coupling for attachment of users delivery hose

Inlet shutoff manual valve

20 gallon spill containment sump with drain to pump inlet

Outlet check valve

1" threaded fitting for attachment of outlet pipe to tank

Pressure relief valve


Controller includes:


Level transmitter for installation in 2" tank fitting

90% and 95% visual alarms

Tank leak alarm

Audible alarm horn activated by alarms above

Power available indicator

Control power on-off switch

Pump start/stop pushbuttons

Top-off/hose drain mode pushbutton

Pump starter

NEMA3R control enclosure

Mini SmartPump pump compartment

Standard Mini SmartPumps include a 2 GPM pump. Optional 7, 10, 17 or 25 GPM pumps are available.

  Automatic FuelPort
 
Back to Fuel Supply Main Page
 