Jupiter Load Bank

The Jupiter Load Bank is a completely self-contained, freestanding unit which includes all resistive load elements, load control devices, load element branch circuit fuse protection, main load bus and terminals, cooling system, control power supply, unit controller and malfunction detection system and NEMA type enclosure.

Ultra-high capacity load testing of generators or electric dynamometer testing of large engines and turbines is achieved with the Simplex Jupiter Load Bank. The unit capacity of the Jupiter is 4500KW, resistive, unity power factor. Jupiters may be used singly or in systems of multiple units which yield total capacities of tens or hundreds of megawatts.

The Jupiter is a single or dual voltage Load Bank suitable for all common 60 and 50 Hertz voltages up to 600V. Loads are stepped in any increment of 50KW, or, optionally, in fixed steps to 5KW or infinitely variable.

Jupiter Cooling Fan and Motor

Cooling System: Using an ultra high volume forced air cooling system, up to 80,000CFM

Load Control: Master load toggle switch and load step toggle switches

 

Jupiter Stationary Load Bank

Jupiter indoor configuration.
Exhaust hood required for exterior use.


Features

Self-contained load and control system

Utilizes the UL Recognized, “Powr-Web” load element


Branch circuit fuse protection of load elements

Color coded and numbered wiring; power wiring 150°C

Plated bus bar


Simplex Load Banks can be used to satisfy the requirements of the National Fire Protection Association (NFPA) for emergency stand-by power systems.
GENERAL SPECIFICATIONS

Capacity
4500KW; Resistive, 1.0 power factor

Voltage
All common 3-phase
60 and 50 Hz voltages:
60 Hertz: 208V, 220V, 240V, 416V, 440V, 450V, 460V, 480V, 575V, 600V
50 Hertz: 190V, 200V, 208V, 380V, 400V, 416V

Frequency
50, 60 Hertz

Load Steps
50 KW resolution standard
1-5-10-25KW resolution available

Fan/Control
Internal, from load bus. Control circuits at 120V via transformer. The cooling fan operates at 3-phase line voltage. Load control circuits and fan motor control operate at 120V. Control circuits are fused. Control circuit fuses are 100,000 A.I.C., 600V rated. External, 480/240V, supply for humidity controller, when ordered.

Cooling
Forced air, vertical airflow, top exhaust. 3-phase, TEFC motor driving cast aluminum fan blade. Circuit breaker combination motor starter.

Airflow
80,000 CFM

Duty Cycle
Continuous
 
Dimensions and Key Features Diagram

Stationary Load Banks:
Applications and General Specifications,
Features and Options, and Engineer’s Specifications

 
  Benefits

Modular enclosure design with separate and isolated control and power sections

NEMA-3R, oversize control section with generous cable connection space

Vertical airflow, exhausts hot air above level of personnel and away from buildings, pavement etc.

Comprehensive overload, short circuit and malfunction protection

Slide-out, tray mounted load elements

Highly standardized, based upon extensive product line spanning from 5KW to 3MW
 Jupiter Stationary Load Bank Control Compartment
 

Principle Systems and Components

  Fan/Control
Internal, from load bus. Control circuits at 120V via transformer. The cooling fan operates at 3-phase line voltage. Load control circuits and fan motor control operate at 120V. Control circuits are fused. Control circuit fuses are 100,000 A.I.C., 600V rated. External, 480/240V, supply for humidity controller, when ordered.

Load Elements
Simplex “Powr-Web” open wire, helically wound, chromium alloy, thermally derated to 60%. 5% tolerance, 2% balance, .995 p.f.
UL Recognized.

Load Control
Branch circuit contactors, each 50 KW step. Contactors have enclosed silver surfaced contacts, 120V coils; electrically operated and electrically held.

Element Circuit Protection
Branch circuit fuses, each 50KW branch circuit, 70A, 200kAIC, current limiting type.

Temperature
Maximum ambient temperature: 125°F
Exhaust rise: RISE = KW X 3000/CFM (note: as airflow is not laminar, exhaust air temperatures are not equal at all points at the plane of air exhaust. Some parcels of air may reach approximately 575°F before mixing.)

System Protection
Fan failure, high exhaust temperature, high intake temperature; lockout and alarm.

 
Enclosure

Modular enclosure consists of three parts:

1. NEMA-3R rainproof power section including load elements and cooling fan

2. NEMA-3R control section, thermally and electrically isolated from power section

3. Exhaust hood. Mounts atop power section. Vertical flow with rain separators. Hood may be deleted and a duct flange provided for indoor applications where air is exhausted through a duct to the outdoors.

All panels for access to serviceable components are hinged doors with stainless steel hinges and lockable latches. All exterior fasteners are stainless steel.

The Load Bank enclosure is of double wall construction for cool exterior and thermal isolation of the load elements. Cooling airflow through the enclosure is vertical with cold air intake at the bottom and hot air exhaust out the top. Intake and exhaust openings are screened. All parts of the enclosure are abrasive blasted or chemically etched, primed and finished with a color as specified. The exhaust hood which is exposed to high air temperatures is unpainted galvanized steel.

 
 Saturn Stationary Load Bank Control Panel

Power Wiring
150°C insulated; color coded.

Control Wiring
105°C, color coded and/or numbered.

Power Connection
Plated bus bar within an oversize terminal junction box.