Water LBW-Series |
LBW-Series
|
Load Elements
Water immersion type, NiCr conductor, incolloy clad, screw plug
mounting (individually replaceable)
Monel or stainless steel cladding available
Load Control
Branch circuit magnetic contactors, each load step circuit
Short Circuit Protection
Branch circuit fuses, each load step circuit. Fuses are 200KAIC,
current limiting type
Power Wiring
150°C silicone insulated, color coded
Control Wiring
105°C insulated, numbered and/or color coded
Power Connection
Power distribution block with line side pressure terminals
Malfunction Detection System
Sensors, lockout circuits and alarms for: high water temperature,
low water level/loss of flow, high pressure

Water Flow Control
Inlet supply solenoid valve; manual isolation ball valves on
inlet and outlet
Drain ball valve
Coolant
City water, closed-loop heat exchanger, natural water (river,
lake, etc.), brine, or sea water
Minimum Coolant Flow
10GPM per load cell (100KW)
Water Connection
1, 2 or 4, as required by flow
Control Panel
Local or remote, includes:
1. Control power on-off pushbuttons
2. Load step switches, and total load master control switch
3. Neon indicators: Normal Operation, Control Power Available,
and alarm indicators - High Temp, Loss of Low/Low Level, Over
Pressure
Capacity 5KW-600KW; Resistive, 1.0 p.f. Voltage to 600V AC,1-phase or 3-phase to 350V DC 60 Hertz: 120V, 240V; 1-phase 208V, 220V, 240V, 440V, 450V, 460V, 480V, 575V, 600V; 3-phase 50 Hertz: 100V, 110V, 220V; 1-phase 190V, 200V, 208V, 220V, 380V, 400V, 420V; 3-phase 400 Hertz: 120V, 200V, 208V, 416V; 3-phase DC: 48V, 60V, 90V, 125V, 180V, 250V, 350V Frequency 50, 60, 400 Hertz; DC Load Steps 25KW, 50KW, 100KW standard. 1-5-10KW resolution available. Cooling Requirements The standard design is for use with an external pressure source. Pump sets are available either for installation within the Load Bank for a suction feed or for freestanding remote installation. Supply water to limit outlet temperature to less than 180°F. KW = GPM x Temp. Rise (F) x .16 GPM = KW / (Temp. Rise x .16) Temp. Rise (F) = KW / (GPM x .16) Standard unit accepts water to 180PSI. Optional designs accept higher pressures. Pressure drop across Load Bank approximately 5PSI. Standard units accept fresh water. Optional designs accept sea water. Consult Simplex for acceptability of water additives. Particulates must be less than 150 microns or a filter is required. Control Power Internal or external source All control circuits operate at 120V, 1-phase, 60 Hz Isolation transformer supplied when line voltage greater than 120V, 120/240V or 120/208V Local Ambient Temperature 120°F max. Load Cell Test Pressure 180PSI standard Higher pressures available Duty Cycle Continuous Dimensions and Key Features Diagram |

Simplex Inc., 5300 Rising Moon Road, Springfield, IL 62711-6228 800-637-8603 217-483-1600 (24 Hr.) FAX 217-483-1616 |