SIMPLEX LARGE PORTABLE LOAD BANK OPTIONS
includes dynaMITE, Electra and Atlas-Megawatt Load Banks

 
Test Instrumentation. Analog Meters. ( 3 1/2" with +/- 2 % accuracy )
OPLB-05
OPLB-06
OPLB-30
OPLB-41
OPLB-43
OPLB-44
OPLB-95
OPLB-96
OPLB-100
OPLB-101
OPLB-105
OPLB-106
OPLB-107
Kilowatt Meter
Total Load Kilowatt Meter (requires option 5-56 or 5-57)
Total Load Ammeter with 4 position phase transfer switch (requires option 5-56 or 5-57)
Power Factor Meter
Kilovar Meter
Total Load Kilovar Meter (requires option 5-56 or 5-57)
Ammeter with 4-position switch and 3 current transformers installed
400 hertz Ammeter with transformers
Voltmeter with 4-position switch
400 hertz voltmeter meter with 4 position switch
Frequency Meter
400 hertz Frequency Meter
Running Time Meter
Test Instrumentation. Analog Meters. ( 4 1/2" with +/- 1 % accuracy )
OPLB-10
OPLB-11
OPLB-15
OPLB-20
OPLB-25
OPLB-40
OPLB-42
OPLB-45
Kilowatt Meter
Total Load Kilowatt Meter (requires option 5-56 or 5-57)
Voltmeter and Ammeter with 4-position phase transfer switch
Frequency Meter
Total Load Ammeter with 4-position phase transfer switch (requires 5-56 or 5-57)
Power Factor Meter
Kilovar Meter
Total Load Kilovar Meter (requires 5-56 or 5-57)
Test Instrumentation, Digital Meters
OPLB-200
OPLB-205
OPLB-210
OPLB-215
OPLB-220
OPLB-225
OPLB-230
OPLB-235
Voltmeter with 4-position switch
Ammeter with 4-position switch
Total Load Ammeter with 4-position switch (requires option 5-56 or 5-57)
Frequency Meter
Kilowatt Meter
Total Load Kilowatt Meter (requires option 5-56 or 5-57)
Kilovar Meter
Total Load Kilovar Meter (requires option 5-56 or 5-57)
Instrumentation Accessories
OPLB-56
OPLB-57
Total Load Current Transformer Bank, window type with plug-in cable (cables pass through windows)
Total Load Current Transformer Bank with plug in metering cable. Terminal junction type accept up to 5000A cable connections per side. Multiple Load Banks connect to bus bar on line side. One set of load cables, supplied by others, connect to bus bar on load side.
Load System
OPLB-66
OPLB-69
OPLB-71
OPLB-73
OPLB-74
1 KW load step resolution (N/A dynaMITE 300)
Total Load control of remote auxiliary Load Bank installed in panel of master Load Bank
Extended internal power capability to 480V, 3 phase, 50-60 hertz. (dynaMITE 300 only)
Remote control cable for remote control panel - 50' length. (N/A dynaMITE 300)
Total Load control cable for auxiliary Load Banks from master Load Bank - 50' length.
Mechanical
OPLB-79
OPLB-82
OPLB-83
OPLB-84
OPLB-75
OPLB-85
OPLB-86
OPLB-87
OPLB-89
Protective storage and weather cover for dynaMITE 300 and dynaMITE 400
Protective storage and weather cover for Electra Load Banks
NEMA-3R version of Electra
NEMA-3R version of dynaMITE
Locking door handles
Highway trailer, dynaMITE
Highway trailer, Electra
Highway trailer, Atlas
"SHIP/STOR" shipping and storage container (N/A Reactive Unit)

SIMPLEX COMPANION LOAD BANKS 
 MODEL CAPACITY LOAD STEP
RESOLUTION
Auxiliary 300 300 KW at 240/480V, 3-ph.; 225 KW at 208/416V, 3-ph.; 200 KW at 240V, 1-ph. 50 KW
Auxiliary 400 400 KW at 240/480V, 3-ph.; 300 KW at 208/416V, 3-ph.; 267 KW at 240V, 1-ph. 50 KW
Auxiliary 500 500 KW at 240/480V, 3-ph.; 375 KW at 208/416V, 3-ph.; 250 KW at 240V, 1-ph. 50 KW
Auxiliary 600 600 KW at 240/480V, 3-ph.; 450 KW at 208/416V, 3-ph.; 400 KW at 240V, 1-ph. 50 KW
Auxiliary 650 650 KW at 240/480V, 3-ph.; 488 KW at 208/416V, 3-ph.; 434 KW at 240V, 1-ph. 50 KW
Reactive 345, use with Electra-460 345 KVAR at 240/480V, 3-ph.; 259 KVAR at 208/416V, 3-ph. 3.75 KVAR
Reactive 420, use with Electra-560 420 KVAR at 240/480V, 3-ph.; 315 KVAR at 208/416V, 3-ph. 3.75 KVAR
Reactive 495, use with Electra-660 495 KVAR at 240/480V, 3-ph.; 371 KVAR at 208/416V, 3-ph. 3.75 KVAR

Back to dynaMITE 155 Page.

  
Back to dynaMITE 300 Page.

  
Back to dynaMITE 400 Page.

  
Back to Electra Page.

  
Back to Atlas-Megawatt Page.

Back to Load Bank Main Page
 