Radiator
LBD-Series |
|
||||||||||||||||||||||||||||||||||||||||||||||||||
Simplex LBD-Series Load Banks are intended for use with water cooled engine generator sets equipped with unit mounted radiators. The essential consideration for installation is that it be located somewhere within the radiator air outflow. Installation is simple and adaptive to site/system conditions in numerous ways, including direct bolted attachment to the radiator, mounting within an air duct, wall mounting over the air outflow opening, indoors or outdoors. Since the design is adaptive to varying site conditions, Simplex LBD-Series Load Banks are ideal for after market retrofit. Many options are available to suit individual requirements and simplify installation. LBD-Series Load Banks are of a modular-building block design. Simplex builds them up from stock modular parts to match your radiator or duct dimensions exactly. The control section's standard location is on the left side, but it may be ordered on the right side. A control section may be required on both sides in some applications. |
![]() Features This product has earned the UL Listing Mark Utilizes the UL Recognized Powr Rod load element Branch circuit fuse protection of load elements Magnetic contactor control of load Multiple step load configurations 150°C XLP insulated power wiring Power terminal block with standard size pressure terminals for common building wire Local or remote control available Manual or automatic control available 120V control circuits Install at any point within radiator air outflow Install indoors or outdoors (via option modification) Many installation accessories available Galvanized steel construction Automatic over temperature protection Control components separate and isolated from load elements Continuous duty |
Reliability Exercise and testing of standby generator sets to assure readiness and eliminate the negative effects of both prolonged standby and of no-load exercise. Base load leveling to eliminate the deleterious effects of low load operation: manual application or fully automatic in response to dynamic load demand. Automatic protection against generator reverse power and motoring of prime mover by power regenerated by inertial loads. Options Mounting Angles Mounting Feet Nema-3R Modification Automatic Current Sensing Operation VM-AM-FM Meters with switches KW Meter Cooldown Timer Auto-Exercise Anti-Condensation Heaters |
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||
Total Width = Opening Width + 2" + Control Section(s) Width 10" x 24" Control Section = 19.355" W 20" x 24" Control Section = 11.355" W 20" x 48" Control Section = 13.355" W Note: A Control Section may be required on both sides for some applications. Due to system complexity, actual dimensions may vary. |
![]() Remote Control Panel 15" W x 15" H x 10" D 24" W x 24" H x 12" D |
||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||
![]() |
||