Stationary Load Bank Features |
|||
Features Options |
Utilizes the UL Recognized Powr-Web load element Branch circuit fuse protection of load elements Magnetic contactor control of load Multiple step load configurations 150°C insulated power wiring, color coded Copper plated bus bar Integral cooling fan 120V control circuits Fused control circuits Automatic over temperature and fan failure protection Continuous duty NEMA-3R outdoor or NEMA-1 indoor |
Malfunction detection system provides automatic load disconnect and alarm on sensing of an abnormal operating condition. The systems consists of: Cooling air intake temperature switch, set at 120°F, to sense recirculation of load bank hot exhaust air or an ambient temperature above the rating of the load bank Cooling air exhaust temperature switch, set 75°F above maximum rise at maximum ambient, to sense restricted cooling airflow, recirculating air, loss of airflow. Air pressure switch to sense for positive cooling airflow Automatic load disconnect/lockout circuit Remote alarm contacts |
![]() Integral Forced Air Cooling System Motor drive propeller fan Fan blade, shrouded for high efficiency Motor control contactor Motor circuit breaker Fan motors normally operate at load bank line voltage Motors for outdoor load banks are totally enclosed Motors for indoor load banks are open-drip-proof |
Stationary Load Bank Options |
|||
2% or 1% analog type; 2% digital type: AC voltmeter with 3-phase switch AC ammeter with 3-phase switch Frequency meter Kilowatt meter Kilovar meter Power factor meter Kilowatt-hour meter Recording instruments DC voltmeter DC ammeter Enclosure Options Indoor version, NEMA-1, with exhaust duct adaptor flange Optional hot air exhaust hoods/deflectors, including exhaust to one side only, straight-up vertical exhaust Marine environment |
System
OptionsOvervoltage protection Ground fault protection Anti-condensation internal space heaters with humidistat control Fan/control power supplied from an external source instead of from the Load Bank main bus Load Options Variable load steps (0-1KW) Inductive load to obtain lagging power factor Capacitive load to obtain leading power factor ![]() Main Disconnect Switch Installed on Load Bank Supplied installed in separate enclosure for remote mounting |
![]() Highway Trailer Conforms to applicable Federal and DOT standards Load Options Variable load steps (0-1KW) Inductive load to obtain lagging power factor Capacitive load to obtain leading power factor |
|
Saturn page, Saturn-HV page, Triton and Trident page Request Quote. Stationary Load Bank Applications and General Specifications and Engineers Specifications. |
|||