Swift-e AC
Portable
Standard
10KW
Plus
15KW
Ultra
20KW
Swift-e DC
Portable
Junior
7.5KW
Standard
10KW
Super
15KW

|
Swift-e
Portable Load Bank
Quick and easy testing of small
generators is possible with the Simplex Swift-e Portable Load
Bank. Fully self-contained, lightweight and hand transportable,
the Swift-e can be used to test and maintain engine generators,
inverters, batteries, battery chargers, rectifiers and small
UPS systems. Swift-es are available as AC or DC units with
capacities up to 15,000 watts of load switchable in 250W increments.
AC Swift-es are rated 120/240V dual voltage, single phase.
DC Swift-es are rated 12V, 24V, 36V or 125V, single voltage
or dual voltage in 2X multiples (12/24, 18/36 or 62/125). All
control and cooling circuits operate from the source under test.
Complete test instrumentation and connection cables are provided.

Test Instruments and
Control Panel
2.5" square, 2%
accuracy panel meters:
AC
voltmeter, 0-300V
(or DC voltmeter)
AC
ammeter, with current transformer
0-50/100A
dual scale (Swift-e)
0-75/150A dual scale (Swift-e+)
(or DC ammeter with shunt)
Ammeter
range selector switch
Frequency
meter, 45-65Hz
(deleted in DC units)
Instrument fuses
Master load switch, applies all load preset with load step toggle
switches
Load step toggle switches
Fan/control power toggle switch
|

Features
Load Elements:
Sealed, tubular-type element consisting of nichrome resistance
wire sealed within an incolloy sheath (nickel alloy). Electrically
dead exterior of element reduces hazard of electric shock and
short circuit of elements.
Element is rustproof,
vibration and shock proof.
Load Control:
Panel mounted toggle switches for each load step and master load
control. Main contactor for master load control/block loading.
Load Element Circuit
Protection:
Main circuit breaker with overload/short circuit trips.
Malfunction Detection
System: Over temperature
sensor to protect against a cooling failure which could damage
the Load Bank or present a safety hazard to the operator. Overvoltage
sensor to protect against incorrect connection of load bank (connection
of 240V to 120V circuits). Each sensor trips the main contactor
and activates the alarm indicator.
Connection cable set, 10', with ring lug terminations.
NEMA type 1 enclosure, aluminum construction, painted beige with
a blue control panel. Includes rubber feet, carry handles and
cable storage hooks.

|
Simplex Load Banks can
be used to satisfy the requirements of the National Fire Protection
Association (NFPA) for emergency stand-by power systems. |
|
SPECIFICATIONS
Swift-E AC
Capacity
Swift-E: 10,000 watts
Swift-E+: 15,000 watts
Swift-E Ultra: 20,000 watts
Voltage
Reconnectable
120V or 240V, single-phase
Frequency
60 Hertz (50
Hertz optional)
Cooling
On board fans,
500CFM
Control Power
Internal,
from power source under test
Weight
Swift-E, Swift-E+: 40 lbs.
Swift-E Ultra: 80 lbs.
Dimensions
Swift-E, Swift-E+: 20"
W x 16.5" H x 14" D
Swift-e Ultra: 20" W x 30" H x 14" D
Swift-E DC
Capacity
Swift-E
Jr.: 7500W
Swift-E DC Standard: 10,000W
Super Swift-E: 15,000W
Voltage
Swift-E
Jr., Swift-E+
DC Standard: Single voltage or 2X dual voltage, 12V, 24V,
36V, and 125V
Super Swift-E: Single voltage or 2X dual voltage, 24V,
36V, and 125V
Frequency
60 Hertz (50
Hertz optional)
Cooling
On board fans,
500CFM
Control Power
Internal,
from power source under test
Weight
Swift-E
Jr.: 35 lb.s
Swift-E+ DC Standard, Super Swift-E: 40 lbs.
Dimensions
Swift-E
Jr., Swift-E+
DC Standard, Super Swift-e: 20" W x 16.5"
H x 14" D
Options
AC KW Meter,
1-ph. or 3-ph.
DC Voltmeter
Duffle bag
Cart
Variable Load Step, 0-250W
NEMA Plugs
Cam-Lok Connectors
Clamps
Sales
Bulletin
Dimensions and Key Features
Diagrams: Swift-e or Swift-e
Ultra
|
|
|
|
|
SWIFT-E
AC PORTABLE LOAD BANK |
|
MODEL |
CAPACITY |
VOLTAGE |
FREQUENCY |
LOAD
STEPS |
COOLING |
WEIGHT |
|
Standard |
10KW |
Reconnectable
120V or 240V, 1-ph.
|
60 Hz
(50 Hz optional)
|
2 x 250W,
1 x 500W,
1 x 1000W,
4 x 2000W |
500 CFM,
on board fans
|
40 lbs. |
|
Plus |
15KW |
2 x 250W,
1 x 500W,
2 x 1000W,
6 x 2000W |
40 lbs. |
|
Ultra |
20KW |
2 x 250W,
1 x 500W,
2 x 1000W,
6 x 2000W,
1 x 5000W |
80 lbs. |
|
SWIFT-E
DC PORTABLE LOAD BANK |
|
MODEL |
CAPACITY |
VOLTAGE |
FREQUENCY |
LOAD
STEPS |
COOLING |
WEIGHT |
|
Junior |
7.5KW |
12, 24, 36,
or 125V DC
single or dual
|
60 Hz
(50 Hz optional)
|
1 x 500W,
1 x 1000W,
3 x 2000W |
500 CFM,
on board fans
|
35 lbs. |
|
Standard |
10KW |
2 x 250W,
1 x 500W,
1 x 1000W,
4 x 2000W |
40 lbs. |
|
Super |
15KW |
24, 36, or 125V DC
single or dual
|
2 x 250W,
1 x 500W,
2 x 1000W,
6 x 2000W |
40 lbs. |
|