Rental Duty                                                Infinity-200R
                     Dual Voltage Load Bank                                             200 KW Digital Load Bank
                       208-240/416-480vAC
                                                                                           with Network Capability



                  Overview

                  •  Infinitely variable: 0-200kw, 208-480v
                  •  Infinitely flexible: compact, lightweight,
                    flush sides, 360-degree casters
                  •  Infinitely expandable: digitally network
                    to as many as 40 Infinity or Powerstar
                    load banks
                  Description

                  The new Simplex Infinity 200 is simply
                  the most advanced factory-standard
                  load bank available anywhere. Digitally
                  controlled infinite loads—simply enter
                  any value from zero to max, and the
                  load bank goes there. Ramp-up,
                  ramp-down, infinitely. Roll-in, roll-out,
                  360-degree casters, forkliftable, connect
                  up to 2 x 4/0 per phase. Daisy chain up
                  to 40 units (that’s 8000kw- maybe not
                  infinite capacity, but who’s counting at
                  that point). Single-point control of the
                  chain of load banks. Single-point data
                  acquisition of the chain. 200kw at 240
                  and 480v, 3-phase; 150kw at 208 and
                  416v, 3-phase, 133kw at 240v, single-
                  phase, all in the smallest and lightest   Infinity-200  or Powerstar Load Banks
                  package available.                  can be networked together via RS-
                  Upon initial start-up , the Infinity   232 cables connected from the “out”
                  controller measures the applied voltage   connector on the first unit to the “in”   •  Magnetic contactor control of load
                  and calibrates the loads to that voltage.   connector on the next, and then “out-  •  Digital load control
                  Therefore, at intermediate voltages,   to-in” in succession until the desired   •  Use at all common 50 or 60 Hertz
                  such as 440v, 416v, 220v, 208v, the   number of units are connected. All   voltages, to 480V AC
                  load bank controller calibrates for the   control and metering is provided
                  reduced capacity. Within the capacity of   from a single hand-held controller. All   •  Digital Power Transducer, standard:
                  the load bank, the load requested is the   instrumentation values for the total   Volts, Amps, Frequency, Kw
                  load applied.                       network are summed and displayed on   •  150°C XLP insulated power wiring
                                                      the master controller.
                  Also, the Infinity-200 is compatible with                               •  Cam-Type power connectors
                  the Simplex Powerstar-110—daisy     The Infinity-200 is highly portable and   •  Operate fan and control circuits from
                  chain any combination of Infinitys and   easily transported to the job site. The   a common 120V wall outlet, 15’ cord
                  Powerstars.                         Load Bank includes casters, lifting and   provided
                                                      moving handles. Power connections are
                  The Infinity-200 is a digitally controlled   plug-in to Cam-Type connectors. Control   •  Forced air cooled, integral cooling
                  load bank with network capability. All   and cooling fan power is obtained from   fans
                  control is via a hand-held touchscreen   a common 115v, 15A outlet via the   •  Fan motors protected by fuses
                  controller connected to the load bank   included connection cord.       •  Control circuits fused
                  via a supplied RS-232 network cable.
                  The load bank includes a digital    Features                            •  Comprehensive malfunction detection
                  power transducer with meter displays                                      system:
                  on the touchscreen. Load is applied   •  Unique compact 200kw load bank    -  Overtemperature and fan failure
                  via a screen keypad. Any number of   •  Lightweight and compact             protection
                                                      •  Portable, self-contained           -  Overvoltage protection
                                                      •  “Powr-Web” elements              •  Continuous duty
                                                      •  Branch circuit fuse protection of load   •  NEMA-1 enclosure
                                                        elements                          •  Casters and handles provided









                                                                                   Rental Centers: Springfield, IL; Atlanta;
                                                                                   Baltimore; Boston; Denver; Houston; Minneapolis



          SOS-Infinity-1409-03.01a.indd   1                                                                          7/11/2016   1:13:30 PM