Load Banks Fundamentals
Small Portable
Watt-Muncher
Swift-e
MicroStar
PowerStar
NorthStar
Large Portable
Merlin
dynaMITE
Electra
Atlas-Megawatt
Load Cube
Stationary
Polaris
Neptune
Mars
Mars-HV
Saturn
Saturn-HV
Titan
Trident
Trailer
dynaMITE Trailer
Atlas-Megawatt Trailer
Neptune Trailer
Trident Trailer
Radiator Cooled
LBD-Series
Water Cooled
LBW
Digital Control Systems
D-Series Controller
AutoTest Software
Fuel Supply Fundamentals
Mission Critical
Management System
Filtration Systems
Joe Filter
Filter Tank
SmartFilter
Fuel Tanks
Reliant Series
SST Series
Tank Filling Systems
FuelPort
Automatic FuelPort
SmartPump
Fuel Pump Sets
Packaged Pump Sets
Skid Mounted Pump Sets
Control and Monitoring
Digital Control
Analog Control
TC-9 Fuel Fill Controller
TC-8 Tank Alarm Panel
Product Warranties
Maintenance Schedules
Load Bank Maintenance Schedule
Fuel Supply Maintenance Schedule
Conditions of Sale
Technical Data & Tools
Load Bank Technical Data
Fuel Supply Technical Data
Troubleshooting
Load Bank Troubleshooting
Fuel Supply Troubleshooting
FAQ
About Simplex
Simplex Onsite
History
Team
Facility
Inquiry Form
Key Contacts
Location & Directions
Request a Quote
Find a Representative
Request Quote
Find Representative
Product Search
Load Banks
Small Portable
Large Portable
Merlin
dynaMITE
Electra
Atlas-Megawatt
Load Cube
Stationary
Trailer
Radiator Cooled
Water Cooled
Digital Control Systems
Load Bank Fundamentals
Service and Support
Home
Merlin
Simple rugged product for field or line use maintenance, testing and performance proving of mid-range engine generator sets, UPS and other power systems
Capacity
100KW-400KW
Voltages
240/480vAC, 3-phase, 240vAC single-phase, re-connectable
Load Type
Resistive
Frequencies
50/60 Hz
Power Factor
1.0
Load Steps
5 KW resolution standard.
dynaMITE
Network capable, digitally controlled Load Bank for field or line testing:
•
Mid range generators when used as a single unit
•
Large generators when combined and networked with other dynamite or Electra load banks
Capacity
315KW at 480V, 3-phase
290KW at 240V, 3-phase
217KW at 208V, 3-phase
208KW at 240V, single phase
Voltages
Operator selectable:
High: 250-480V AC, 3-phase
Low: 12-240V AC, 1 or 3 phase
Load Type
Resistive
Frequencies
50/60Hz standard
Power Factor
1.0
Load Steps
1 KW resolution standard.
Electra
Nework capable, digitally controlled load bank for field or line testing of:
•
Mid range generators when used as a single unit
•
Large generators when combined and networked with other dynamite or Electra load banks
Capacity
450-500-550-600-650-700kw
Voltages
240/480vAC, 3-phase, 240vAC single-phase, re-connectable
Load Type
Resistive
Frequencies
50/60Hz standard
Power Factor
1.0
Load Steps
5 KW resolution standard
Atlas-Megawatt
Network capable, digitally controlled Load Bank for field or line testing of:
•
Large generators
•
Large distribution systems
•
Shipboard generators
Capacity
1000kw
Voltages
240/480vAC, 3-phase, 240vAC single-phase, re-connectable
Load Type
Resistive
Frequencies
50/60 Hz
Power Factor
1.0
Load Steps
5 KW resolution standard
Load Cube
Purpose-built product for portable duty. Network capable, digitally controlled load bank for field testing of:
•
Very large systems, single or paralleled
•
Shipboard systems
•
Oilfield systems
Capacity
2500kw, 1875kvar 0.8 power factor (all-in-one load bank)
Voltages
480vAC, 600vAC 3-phase
Load Type
Resistive / Reactive
Frequencies
50/60 Hz
Power Factor
0.8
Load Steps
5 kw, 3.75 kvar