Load Banks Fundamentals
Small Portable
Watt-Muncher
Swift-e
MicroStar
PowerStar
NorthStar
Large Portable
Merlin
dynaMITE
Electra
Atlas-Megawatt
Load Cube
Stationary
Polaris
Neptune
Mars
Mars-HV
Saturn
Saturn-HV
Titan
Trident
Trailer
dynaMITE Trailer
Atlas-Megawatt Trailer
Neptune Trailer
Trident Trailer
Radiator Cooled
LBD-Series
Water Cooled
LBW
Digital Control Systems
D-Series Controller
AutoTest Software
Fuel Supply Fundamentals
Mission Critical
Management System
Filtration Systems
Joe Filter
Filter Tank
SmartFilter
Fuel Tanks
Reliant Series
SST Series
Tank Filling Systems
FuelPort
Automatic FuelPort
SmartPump
Fuel Pump Sets
Packaged Pump Sets
Skid Mounted Pump Sets
Control and Monitoring
Digital Control
Analog Control
TC-9 Fuel Fill Controller
TC-8 Tank Alarm Panel
Product Warranties
Maintenance Schedules
Load Bank Maintenance Schedule
Fuel Supply Maintenance Schedule
Conditions of Sale
Technical Data & Tools
Load Bank Technical Data
Fuel Supply Technical Data
Troubleshooting
Load Bank Troubleshooting
Fuel Supply Troubleshooting
FAQ
About Simplex
Simplex Onsite
History
Team
Facility
Inquiry Form
Key Contacts
Location & Directions
Request a Quote
Find a Representative
Request Quote
Find Representative
Product Search
Load Banks
Small Portable
Watt-Muncher
Swift-e
MicroStar
PowerStar
NorthStar
Large Portable
Stationary
Trailer
Radiator Cooled
Water Cooled
Digital Control Systems
Load Bank Fundamentals
Service and Support
Home
Watt-Muncher
Low voltage DC Load bank for testing and maintenance of:
•
Battery systems
•
Rectifiers
•
Battery chargers, Power Supplies, Hybrid vehicles
Capacity
DC – 125v to 15KW
Voltages
12/24DC to 150A
Load Type
Resistive
Frequencies
60 Hz (50 Hz optional)
Power Factor
N/A
Load Steps
Nominal 1.0A
Swift-e
Testing and maintenance of small generators to 20KW; field or line use:
•
Residential standby
•
Contractor generators
•
Marine generators
•
RV generators
•
Small wind turbines
•
120/240v panelboards and distribution
•
Inverters
•
Small UPS
Capacity
10KW, 15KW, 20KW
Voltages
120/240vAC single-phase
Load Type
Resistive
Frequency
60 Hz
Power Factor
N/A
Load Steps
250w Nominal
MicroStar
Precision heat generation via adjustable heat levels and airflow for comprehensive testing of:
•
Data center hot aisle/cold aisle cooling systems
Capacity
4.4KW, 13.15KW, 16.1KW, 17.5KW
3.5KW, 10.5KW, 12.85KW, 14KW
Voltages
120/240vAC single-phase
Airflow
Speed control, 400-1900 CFM
Connection
Power inlet/plug
Width
Fits 19" server rack
Height
10U high
PowerStar
Digitally controlled, multiple units may be networked to achieve desired capacity:
•
Field testing & maintenance
•
Product line testing
•
Large systems via networking
Capacity
110KW
Voltages
Dual, nominal 240/480vAC, 3-phase
208-240/416-480vAC, 3-phase, 60Hz
190-220/380-460vAC, 3-phase, 50Hz
110-240vAC, 1-phase, 50-60Hz
Load Type
Resistive
Frequencies
50, 60 Hz
Power Factor
1.0
Load Steps
Digital load control, 5KW resolution
NorthStar
Designed to be used in Canada, digitally controlled, multiple units may be networked to achieve desired capacity:
•
Field testing & maintenance
•
Product line testing
•
Large systems via networking
Capacity
150KW
Voltages
600vAC, 3-phase, 60Hz
Load Type
Resistive
Frequencies
60 Hz
Power Factor
1.0
Load Steps
Digital load control, 5KW resolution