Fuel Tanks : Reliant Series

OVERVIEW SPECIFICATIONS DOWNLOADS OPTIONS GALLERY
  Reliant Series Overview

Simplex Fuel Tanks - Reliant Series 150 Gallon Day Tank

The Simplex Reliant Series comprises a standard line of fuel tanks finding application as day tanks and other tank applications featuring integration of intelligent control with pumping and gauging systems.

The Reliant Series is fully compatible for network integration with the full line of Simplex Fuel Supply Systems, including packaged pump systems, tank filling systems, filtration systems, digital fuel and tank management systems and digital monitoring and data systems. The Reliant Series, when supplied with a Simplex digital controller, is MODBUS and Ethernet compatible with most tank gauging systems.

  Reliant Series Features

The Reliant Series is comprised of a highly reliabile line of fuel tanks used as day tanks, main supply tanks, transfer tanks, return tanks, and filter tanks. Manual tanks for use as basic storage tanks are also available.
The Reliant Series is fully compatible for network integration with the full line of Simplex Fuel Supply Systems, including packaged pump systems, tank filling systems, filtration systems, digital fuel and tank management systems and digital monitoring and data systems.
Reliant Series fuel tanks are UL142 listed double-wall constructed suitable for indoor or outdoor use. Rectangular constructed tanks include closed secondary containment. Fire-rated designs are available with UL2080 or UL2085 listings.
Codes and standards: City of Chicago approval #E9135, #E9136; L.A.F.D. Approval - Los Angeles Fire Department approved day tanks - use SST/SRS Series Day Tank; Wisconsin approval #940065U; and Florida EQ #732.
Rectangular tank capacities (gallons) are 50, 75, 100, 150, 200, 275, 325, and 400.
Cylindrical tank capacities (gallons) are 500, 600, 800, 1000, 1200, 1400, 1500, 1800, 2000, and 2500.
Controllers for normal duty products are UL508 listed, Type 1 indoor, Type 3R, 4, 12 indoor/outdoor. Hazardous location controllers are available.
The Reliant Series integrates a tank of required capacity with a level controller and fill control. On-board fill pumps and return pumps are typical. Remote pumping systems are available for filling of multiple tanks, management of multiple source tanks or when required by pipe run or pump size conditions.
Both digital and analog controllers are available. Digital controllers are PLC based and network compatible. Digital controllers utilize both a point sensing float switch input and a 4-20mA analog to-digital input which displays on a panel indicator and provides a 4-20mA output. Analog controllers are based on the time-proven Simplex SST Controller.