Titan 600R
Simplex Titan 600R Load Bank Rental
Testing and maintenance of:
Large AC generators
UPS systems
other power systems
Capacity 240/480v, 3-phase, 60 hertz:
750KVA, 0.8 power factor
600KW resistive, 450KVAR inductive, 1803/901A
208/416v, 3-phase, 60 hertz:
562.5KVA, 0.8 power factor
450KW resistive, 337.5KVAR inductive, 1563/781A81AW
Voltages 40/480v, 3-phase, 60 Hz
Load Type Resistive/Inductive Frequencies 60 Hz
Power Factor Adjustable Load Steps Digital load control, 5 kw, 3.75 kvar resolution
  Mini-Load Cube R
Simplex Mini-Load Cube R 1563KVA Load Bank Rental
Purpose-built product for portable duty. Network capable, digitally controlled load bank for field testing of:
Very large systems, single or paralleled
Shipboard systems
Oilfield systems
Capacity 1563KVA, 1250KW Resistive,
937.5KVAR Inductive
Voltages 480v, 600v, 690v
Load Type Resistive / Reactive Frequencies 50/60 Hz
Power Factor 0.8 Load Steps 5 kw, 3.75 kvar
  Load Cube R
Simplex Load Cube R 3125KVA Load Bank Rental
Purpose-built product for portable duty. Network capable, digitally controlled load bank for field testing of:
Very large systems, single or paralleled
Shipboard systems
Oilfield systems
Capacity 3125KVA, 2500KW Resistive, 1875KVAR Inductive Voltages 480v, 600v, 690v
Load Type Resistive / Reactive Frequencies 50/60 Hz
Power Factor 0.8 Load Steps 5 kw, 3.75 kvar
  Saturn R
Simplex Saturn R 3200/2720KW Load Bank Rental
Testing and maintenance of:
Large AC generators
UPS systems
other power systems
Capacity 3200/2720KW Voltages 480/600V
Load Type Resistive Frequencies 50/60 Hz
Power Factor 1.0 Load Steps 25KW resolution
   Load Ranger R
Simplex Load Banks - Swift-e Small Portable Load Bank
Combine with the Inductive Load Ranger R for 0.8 power factor testing. Testing, maintenance and performance proving of:
Large diesel generators Turbines Paralleled generators
Shipboard generators
Capacity 3000KW Voltages 480/600V
Load Type Resistive Frequency 50/60 Hz
Power Factor 1.0 Load Steps Digital, 5 kw resolution
   Load Ranger IR
Simplex Load Banks - Swift-e Small Portable Load Bank
Combine with the Resistive Load Ranger R for 0.8 power factor testing. Testing, maintenance and performance proving of:
Large diesel generators Turbines Paralleled generators
Shipboard generators
Capacity 2250KVAR Voltages 480/600v
Load Type Inductive Frequency 50/60 Hz
Power Factor 0.8 Load Steps Digital, 3.75 kvar resolution
  Solar 5R
Simplex Load Bank Systems - Solar-5 Load Bank System
Testing and maintenance of:
Large AC generators
UPS systems
other power systems
Capacity 5.0MVA 0.8 power factor, 4.0MW resistive, 3.0MVAR inductive Voltages Low voltage to 690vAC
Load Type Resistive/ Inductive Frequencies 50/60Hz
Power Factor 0.8 Load Steps 5KW / 3.75KVAR resolution